1, installation: user could install the THC’s operation panel on the work interface, or install it at the convenient operation place. Install the main body at a suitable station.
2, height controller: could change the auto cutting height at any time
3, two modes of the setting arc volt:
A, Setting arc volt mode: set the setting arc volt on the operation panel, let the THC work on the setting arc volt status. It’s the traditional work way.
B, sampling arc volt is the setting arc volt: when the THC control the torch finish the HIS and plasma start, and CNC controller open the AUTO signal to THC, and THC will test the arc value as the setting arc when at beginning the AUTO status. It’s suitable for some small plasma.
4, High Sensitivity: adjusting the THC’s sensitivity, could realize the arc volt change 1V, the arc voltage output will change 1.5V~4V, and don’t occur the vibration. So the lifter’s start voltage is closed related to the THC’s sensitivity, Our lifter’s start voltage is 1.5V ~2V.